Analogové výstupy:
Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard: 4, optional: 8
Automatické čištění:
Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Certifikace:
CE, ETL certified to UL and CSA safety standards, UKCA
Demineralised water:
Internal dilution option: Rinse water & Dilution water
Digitální výstupy:
Profibus DP or Modbus RTU
Doba cyklu :
No Dilution
Default: 10 min.
Continuous: 9 min.
Internal Dilution
Default: 15 min.
Continuous 12 min.
Earth connection:
Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Hmotnost:
Max. 35 kg
Instrument air:
Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar
Interference :
Strong reducing agents like hydrosulfide (S2O42–), nitrite (NO2–) > 0.2 mg/L, sulfite (SO32–) >200 mg/L and thiosulfate (S2O32–) > 5 mg/L decrease the blue color and interfere. Oxygen reacts with sulfide and must be absent. Large quantities of color and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere.
Jaký je obsah balení:
EZ1037sc Sulphide Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and 2 x empty 2.5L Reagent Glass Containers with Fittings (for Colour, Buffer)
Kalibrace:
Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced
Materiál:
Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Metoda měření:
N,N-dimethyl-p-phenylenediamine colorimetric method
Mez detekce:
No Dilution
0.025 - 0.5 mg/L S²⁻: 0.025 mg/L
Internal Dilution
0.125 - 2.5 mg/L S²⁻: 0.125 mg/L
0.25 - 5 mg/L S²⁻: 0.25 mg/L
0.625 - 12.5 mg/L S²⁻: 0.625 mg/L
1.25 - 25 mg/L S²⁻: 1.25 mg/L
1.875 - 37.5 mg/L S²⁻: 1.875 mg/L
2.5 - 50 mg/L S²⁻: 2.5 mg/L
Napájení:
100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Odtok:
Atmospheric pressure, vented, min. Ø 32 mm
Okolní teplota:
10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Parametr:
Sulphide
Počet proudů vzorku:
Standard: 1
Optional accessory for 2, 4, or 8 sample streams
Požadavky na vzorek:
Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Přesnost:
Better than 2% full scale range for standard test solutions
Průtoková rychlost:
100 - 300 mL/min
Reagent Requirements:
Keep between 10 - 30 °C
Relé :
5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150)
Rozměry (V x Š x H):
688 mm x 460 mm x 340 mm
Rozsah měření:
No Dilution
0.025 - 0.5 mg/L S²⁻
Internal Dilution
0.125 - 2.5 mg/L S²⁻
0.25 - 5 mg/L S²⁻
0.625 - 12.5 mg/L S²⁻
1.25 - 25 mg/L S²⁻
1.875 - 37.5 mg/L S²⁻
2.5 - 50 mg/L S²⁻
Teplota vzorku:
10 - 30 °C
Tlak vzorku:
By external overflow vessel (open to atmospheric pressure)
Třída ochrany:
IP44
Validation:
Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly
Výstup:
Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP
Záruka:
24 měsíců